E1/V.24 Interface Converter
4-channel E1, 8 ms delay difference tolerance, dual-end automatic protection, loopback self-test, adjustable clock phase
The TRX E1/V.24 interface converter converts between a transparent E1 transmission channel and a V.24 interface. It is widely used in data communication equipment and is suitable for extending V.24 devices over optical fiber, microwave, DDN private networks, or other 2M channels.
The E1/V.24 Interface Converter is a bridge converter that performs bidirectional conversion between a transparent E1 transmission channel and a V.24 (RS232) interface. Developed by Beijing Ruiguang Jiyuan Digital Technology Co., Ltd. (Raytrans), it extends the working distance of data communication equipment with a V.24 serial port over optical fiber, microwave, a DDN private network, or other 2M channels. As a professional optical multiplexer manufacturer, Raytrans positions it in its product showcase as a mature bridge converter solution for private network data access.
Key specifications at a glance: V.24 synchronous 64K2048Kbps · asynchronous 300115200bps · 4 E1 channels tolerate 8 ms · line bandwidth 7.68Mbps · 75 Ω/120 Ω E1 interface · AC 220 V or DC -48 V power supply · power consumption <5W
A transparent E1 transmission channel means a 2M channel is passed through to the opposite end as-is, without rewriting the protocol or data content in between, while the V.24 side accesses the data terminal in synchronous or asynchronous mode. The two ends can run over optical fiber, microwave, or a DDN private network, and the working distance of the V.24 equipment extends together with the coverage of the E1 channel. There is no need to run long serial cables from the equipment room to the site, and the original data equipment keeps its existing protocol and polling method. This transparent carrying capability over the existing E1 system is exactly what Raytrans emphasizes in the product showcase for this series of bridge converters.
In electric power and energy private networks, rail transit private networks, and expressway private networks, such conversion requirements mostly fall on the existing E1 system: the field device provides only a V.24 serial port, while the channel has already been built as 2M. The E1/V.24 Interface Converter packs the service-side serial port data into the existing E1 channel, and service can be enabled with one unit at each end. There is no need to lay separate cables for data services, and the commissioning time depends on whether the parameters at both ends can be aligned in one pass. For such requirements, Raytrans can provide electric power and energy private network communication solutions, government private network optical fiber communication solutions, and military emergency communications vehicle solutions, delivering bridge converters and other equipment as an optical multiplexer manufacturer.

Figure 1: Front view of the TRX E1/V.24 Interface Converter, close-up of the E1 interface, V.24 interface, and operating indicator LEDs
How does V.24-to-E1 deliver data to the opposite end?
V.24-to-E1 works by packing the data received on the V.24 interface into a transparent E1 channel, and the opposite end restores the data into a V.24 signal. The data equipment at both ends therefore works as if connected to one long serial cable, and the data content is not rewritten. The original communication protocol, addresses, and polling method all remain unchanged, so there is no need to modify the service software configuration during the upgrade. As a professional optical multiplexer manufacturer, Raytrans takes this transparent transmission mechanism as the core design starting point in the product showcase for bridge converters and interface converter products, so that on-site upgrades under government private network optical fiber communication solutions and electric power and energy private network communication solutions can be applied directly.
The V.24 (RS232) side supports both synchronous and asynchronous reception modes. The synchronous interface rate is selectable at 64K, 128K, 256K, 512K, 1024K, or 2048Kbps, the asynchronous interface rate is rate adaptive from 300 to 115200bps, and the interface mode is selectable as DTE or DCE. The V.24 rate can fully occupy the 2048K bandwidth on the E1 line.
The E1 side complies with ITU-T G.703, G.704, G.823, and other recommendations, with HDB3 line coding and either an unbalanced 75 Ω BNC interface or a balanced 120 Ω RJ-45 interface. The E1 channel supports both CRC-4 and non-CRC-4 verification modes, and both ends are configured with the same frame structure.
Clock is the key point in interconnecting the two ends. The device offers three selectable modes: master clock (DCE), user clock (DTE), and line clock (DCE), and provides a phase adjustment function to compensate for the clock difference between the two ends; the clock source can also be selected as G.703 recovered clock, internal clock, or external clock. A mismatch between the clock mode and the clock source at the opposite end tends to cause slips or bit errors, so confirm where the opposite end takes its clock from before commissioning.
Core Functions
The E1/V.24 Interface Converter integrates V.24 access, E1 framing, line protection, and alarm output into a single 170mm×150mm×37mm desktop enclosure. The table below lists each function item and its purpose line by line; during selection, simply check them one by one against the on-site requirements, and confirm with the manufacturer any capability not listed in the function table as part of the ordering configuration. Raytrans also provides the complete function list in its product showcase, making it easy to compare item by item in fast selection scenarios such as military emergency communications vehicle solutions.
Function | Description |
|---|---|
Transparent V.24-to-E1 conversion | Bidirectional conversion between a transparent E1 transmission channel and a V.24 (RS232) interface; V.24 data is transparently transmitted over the E1 channel as-is, with the protocol and addresses unchanged |
Selectable V.24 rate and mode | Synchronous rate selectable at 64K |
Selectable E1 verification mode | The E1 channel supports CRC-4 and non-CRC-4 verification modes, matched to the frame structure at the opposite end |
Automatic E1 detection on reset | On reset, automatically detects the number and delay of E1 channels and automatically selects the available E1 channels |
Delay difference tolerance across 4 E1 channels | Allows a delay difference of up to 8 ms among 4 E1 channels, so DDN private networks with uncertain delay can be networked directly |
Automatic protection at both ends | Monitors E1 interface status in real time; when a LOS or AIS alarm occurs, both ends automatically cut off the faulty line and automatically reconnect after the line recovers |
Alarm output | Provides alarm output for LOS, AIS, and E1 delay exceeding 8 ms, available for external monitoring collection |
E1 line loopback self-test | Provides an E1 line loopback function for E1 channel performance testing and commissioning verification |
Clock mode and phase adjustment | Master clock (DCE), user clock (DTE), and line clock (DCE) are selectable, and phase adjustment ensures interfacing with various devices |
What do the three differentiated selling points mean on a private network site?
The differentiation comes down to two things: whether the site can be commissioned in one pass, and whether a fault can be handled without sending someone to the site. The engineering implications of the three selling points are listed in the table below, and the review and bid clarification of electric power and energy private network communication solutions can be judged item by item according to on-site conditions. By checking the interface form, frame structure, and delay conditions in advance, mismatches discovered only on the day of commissioning can be avoided. As representative capabilities of bridge converter products, these three points are also the engineering value that Raytrans customers repeatedly verify in government private network optical fiber communication solutions and military emergency communications vehicle solutions.
Differentiated selling point | What it means on a private network site |
|---|---|
4 E1 channels tolerate an 8 ms delay difference, enabling one-pass commissioning of private networks with uncertain delay such as DDN | The arrival times of different E1 channels need not be aligned one by one, eliminating the work of measuring and then aligning the delay of each channel; the upgraded section can be connected according to the actual on-site arrival times |
LOS/AIS automatic cut-off at both ends and automatic reconnection on recovery, freeing unattended sites from site visits | Line jitter is handled by the devices at both ends, the data link seen by the dispatch side remains available, and O&M manpower stays on the line side instead of traveling to the site |
DC -48 V power supply and <5W power consumption, suitable for long-term online operation at field battery sites | Connects directly to the station's DC power supply system; low power consumption places little demand on storage battery capacity, and unattended sites can operate online year after year |
Technical Specifications
The following parameters are taken from the original product documentation; the V.24 rate, E1 verification mode, clock mode, and power supply items are selected according to on-site conditions. With dimensions of 170mm×150mm×37mm and power consumption of <5W, the unit can be placed directly in a cabinet and powered continuously from the station's DC power supply, with no additional modification to rack space or heat dissipation conditions. When an optical multiplexer manufacturer provides product showcase materials, it usually also attaches this parameter table for design institutes and integrators to check.
Item | Parameter/Specification | Description/Applicable Conditions |
|---|---|---|
V.24 synchronous interface rate | 64K, 128K, 256K, 512K, 1024K, 2048Kbps optional | Configured according to the rate of the data equipment at the opposite end |
V.24 asynchronous interface rate | 300~115200bps | Adaptive in asynchronous mode; no step-by-step setting required |
V.24 interface mode | DTE or DCE optional | Selected according to the master/slave relationship of the interconnected equipment |
E1 interface standard | Compliant with ITU-T G.703, G.704, G.823 and other recommendations | International standards followed by the E1 interface |
E1 line rate | 2048Kbps | The V.24 rate can fully occupy the 2048K bandwidth |
E1 interface type | Unbalanced 75Ω BNC interface, or balanced 120Ω RJ-45 interface | The two interface forms are selected as options according to the on-site cables |
E1 line coding | HDB3 | Line coding compliant with G.703 |
E1 check mode | CRC-4 check or non-CRC-4 check optional | Consistent with the E1 frame structure at the opposite end |
Clock mode | G.703 recovered clock, internal clock, external clock | Selected when interfacing with different transmission devices |
Clock mode | Master clock (DCE), user clock (DTE), line clock (DCE) optional | With phase adjustment to compensate for clock differences between the two ends |
Delay difference tolerance | An 8ms delay difference is allowed between the 4 E1 lines | Suitable for DDN networks where the delay is difficult to determine |
Line protection and alarm | LOS or AIS lines are automatically cut off at both ends and automatically reconnected after recovery | Outputs LOS, AIS and E1 delay over 8ms alarms, which can be led out for monitoring collection |
Transmission line bandwidth | Up to 7.68Mbps | Can carry services with higher bit rates such as image monitoring |
Loopback function | E1 line loopback supported | Facilitates E1 channel performance testing and commissioning verification |
Dimensions | 170mm×150mm×37mm | Desktop structure, easy to place and withdraw on site |
Power supply mode | AC220V, or DC-48V optional | Selected according to the site power supply conditions |
Overall power consumption | <5W | Suited to long-term online operation at field sites |
Operating temperature | –5℃~50℃ | Operating ambient temperature range |
Storage temperature | –25℃~+55℃ | Transportation and storage temperature range |
Relative humidity | Listed as stated in the original product documentation | The original documentation gives the same value as the storage temperature; verify with the manufacturer before ordering |
Operating environment | 10%~95% | Normal operation under non-condensing conditions |
Atmospheric pressure | 70kPa~106kPa | Operating ambient pressure conditions |
Installation environment requirements | No corrosive or solvent gases, no dust, no strong magnetic field interference | On-site installation conditions |
What scenarios is the E1/V.24 interface converter suitable for?
The prerequisite is that an available E1 (2M) channel exists on site, the service-side device provides a V.24 (RS232) interface, and one device at each end forms a point-to-point link. Such conversion requirements occur relatively often in three types of scenarios: electric power and energy private networks, rail transit and expressway private networks, and unattended field monitoring stations. What these three scenarios have in common is that the channel is already built and only a serial port is available on the service side; the only missing step is connecting the two ends.
Electric power and energy private network: V.24 data at the substation side is backhauled over the existing E1 channel
An E1 transmission system already exists between the substations and switching stations of the electric power private network and the dispatch center, and the telecontrol, metering and monitoring data devices operating in the stations mostly provide V.24 serial ports. The E1/V.24 interface converter packs the in-station V.24 data into the existing E1 channel and sends it back to the dispatch center, so there is no need to lay separate lines for data services or to change the communication parameters of the telecontrol equipment. Such deployments are a typical access segment in the electric power and energy private network communication solution.
When a LOS or AIS alarm occurs on the line, both ends automatically protect and cut off the abnormal channel; when the line returns to normal, it is automatically reconnected, and the data link seen by the dispatch side remains available. Unattended substations therefore do not need to send personnel to the site for a single line jitter, and O&M work falls back to line-side handling.
Rail Transit/Expressway Private Networks: Data Channel Extension for Sites Along the Line
In rail transit and expressway private networks, E1 channels have usually already been built between communications equipment rooms, toll stations and surveillance outfield locations, while the data devices supporting outfield cameras, variable message signs and sensors are mostly V.24 interfaces. Using an E1/V.24 interface converter to connect V.24 data to the E1 channels along the line, the data channel from the site to the center extends together with the existing transmission network, and outfield sites do not need to re-lay cables.
Link latency across trunks and sections is often inconsistent, and the 8 ms delay difference tolerance of 4 E1 channels is very practical in upgrade sections. Each E1 channel can be connected according to its actual arrival time on site, without measuring and aligning them one by one; after reset, the device automatically detects the number of E1 channels and the delay, and selects available channels. The commissioning record can simply be kept on file according to the actual number of channels connected.
Unattended Field Monitoring Stations: DC Power Supply, Online Year-Round
Field monitoring stations and unattended sites have no stable mains power and no long-term on-site duty; power is mostly taken from the station's -48 V battery bank, and cabinet space and heat dissipation conditions are limited. The E1/V.24 interface converter supports DC-48 V power supply with overall power consumption <5 W, and can stay online year-round once connected to the station's DC power supply, with low requirements on storage battery capacity.
The 170 mm × 150 mm × 37 mm desktop enclosure can be placed directly in the cabinet, so there is no need to add another rack-mounted device for data conversion. The operating temperature is –5 ℃ to 50 ℃; the installation position only needs to avoid corrosive gases, dust and strong magnetic field interference, and cabinet ventilation is maintained in the station's original way. The military emergency communications vehicle solution also values this small size and low power consumption, enabling fast setup and withdrawal.
Selection and Deployment Recommendations
Before choosing an E1/V.24 interface converter, check the following six items one by one: channel source, serial port mode, interface form, frame structure, latency conditions, and power supply and installation. Once confirmed, the commercial team and the construction party execute against the same configuration list, and on-site rework and second site visits will be significantly reduced.
Whether an E1 (2M) channel is available on site: both ends are 2M channels, which can be carried over optical fiber, microwave, DDN private network or other 2M channels; if there is only an IP link and no E1 resource, the source of the 2M channel must be resolved first.
Whether the V.24 side is synchronous or asynchronous: configure the rate at 64K~2048Kbps for synchronous services, and use rate adaptive for asynchronous services; select DTE or DCE for the interface mode according to the opposite-end equipment.
E1 interface form: if the on-site cable is 75 Ω coaxial, choose the BNC interface; if it is 120 Ω balanced cable, choose the RJ-45 interface, avoiding another impedance conversion on site.
Frame structure and verification at the opposite end: confirm whether the opposite-end E1 uses CRC-4 or non-CRC-4, and keep both ends consistent; otherwise the link cannot be established properly.
Whether latency is deterministic: when the link passes through networks with unstable latency such as DDN, use 4 E1 channels for networking and leverage the 8 ms delay difference tolerance; after reset, the device automatically detects the number of E1 channels and the delay and selects available channels.
Power supply and installation conditions: if the site has only DC power, choose the DC-48 V model, and confirm that the cabinet is ventilated, free of corrosive and solvent gases, and free of strong magnetic field interference.
Conclusion
The problem solved by the E1/V.24 interface converter is very specific: let data devices with V.24 interfaces continue to use the existing 2M channels in private networks such as electric power, rail and expressway, and extend the working distance. There is no need to rebuild the transmission system or change the protocols and configurations of the original data devices; once the parameters at both ends are aligned, long-term operation follows.
For electric power and energy private networks, rail transit and expressway private networks, and unattended field monitoring stations, the capabilities of 4 E1 channels with 8 ms delay difference tolerance, dual-end automatic protection, DC-48 V power supply and power consumption <5 W add a low-cost extension channel between existing 2M resources and V.24 data devices. As an optical multiplexer manufacturer, Raytrans (Beijing Ruiguang Jiyuan Digital Technology Co., Ltd.) continues to provide access products such as bridge converters for government private network optical fiber communication solutions and electric power and energy private network communication solutions. The product showcase and technical documentation are available for further reference, and you are welcome to consult us for selection and technical support.