IDM 120N-GP Telephone Optical Multiplexer
Standalone 120-channel, FXO, FXS, dual 2.5G optical ports, 1+1 protection, 4 groups of E1
The IDM 120N-GP telephone optical multiplexer is used in the product showcase field and is a communication/transmission/dispatching device for industry customers (to be detailed and refined based on documentation)
IDM 120N-GP 2.5G dual-optical-port 120-channel telephone optical multiplexer is a multi-service telephone optical multiplexer that multiplexes 120 voice channels, 4 groups of E1 leased lines and 2 independent wire-speed gigabit Ethernet channels onto a pair of 2.5Gbps optical fibers. Developed by Beijing Ruiguang Jiyuan Digital Technology Co., Ltd., it is used as a high-capacity voice and data aggregation node in electric power private networks, rail transit communication solutions and military and government private networks, and is also a typical product showcase from an optical multiplexer manufacturer for high-density access scenarios.
One unit is deployed at each end. One end connects in-station SPC switching equipment, telephones and data devices and converts them into optical signals, while the other end restores the telephone, E1 and RJ45 interfaces as they are. All services are interconnected at the interface level according to standards, and the configuration of existing equipment does not need to be changed. The unit adopts a standard 19-inch 3U chassis architecture, which facilitates installation in existing private network cabinets with minimal equipment room renovation, making it suitable for rapid deployment in government private network optical fiber communication solutions and military emergency communications vehicle solutions.
Key specifications at a glance: 2×2.5G SFP optical ports (1+1 protection for optical ports) · 120 FXO/FXS channels · 2 independent wire-speed 1000M Ethernet ports · 4 groups of E1 transparent transmission (ITU-T G.703, PCM30/31) · 19-inch 3U chassis

Figure 1: Front view of the IDM 120N-GP telephone optical multiplexer, showing the 19-inch 3U chassis and the layout of operating and alarm indicator LEDs
What kind of equipment is the 2.5G dual-optical-port 120-channel telephone optical multiplexer
The 2.5G dual-optical-port 120-channel telephone optical multiplexer refers to a PCM multiplexer that provides 120 narrowband voice channels, 4 groups of E1 transparent channels and 2 gigabit Ethernet channels in a single chassis, with uplink through two 2.5G SFP optical interfaces. As a high-density multi-service optical multiplexer in the product showcase, voice is encoded into 64Kbps digital voice in PCM30/31 format, with ITU-T G.711 A-law compression per channel, an audio range of 300Hz to 3400Hz, and a loop current of 25mA per channel.
The E1 channel has a bit rate of 2048Kbps and HDB3 line coding, complies with ITU-T G.703, has an impedance of 75Ω, and is transparently transmitted in PCM30/31 frame structure without parsing or rewriting the original time slot content, so the digital trunk equipment and dispatch automation devices at the far end operate with their original parameters. The 2 gigabit Ethernet ports perform 10M/100M/1000M adaptive negotiation and forward through two independent wire-speed ports in compliance with IEEE802.3, meeting the data carrying requirements of a gigabit network optical multiplexer.
The three types of services each occupy an independent channel inside the equipment without contending with each other, and share the same 2.5Gbps link over the optical cable. Monitoring, office and E1 leased lines each use their own interfaces, and the site side occupies only one pair of fiber cores, so sections with scarce optical cable resources do not need to lay or lease separate lines for each type of service. This is also the typical value of multi-service optical multiplexers in private network scenarios.
How to wire the 120 FXO/FXS channels
The 120 FXO/FXS channels are wired in two directions, the exchange side and the user side: FXO interfaces connect to exchange-side resources such as SPC exchanges, while FXS interfaces connect directly to user terminals such as telephones and fax machines. A single unit provides 120 FXO/FXS interfaces as defined by the standard, and the two types of interfaces are configured in combination within the same device, with direction and quantity determined by the project's voice channel requirements.
On-site wiring is verified separately for the exchange side and the user side. Connect voice channels first, then E1 and data cables, with each type of cable routed separately. After wiring is complete, perform unified test calls to confirm that feeding, ringing and voice quality are normal before connecting formal users. The items to verify and the practices are as follows:
FXO side against exchange resources: connect to the user-side ports of SPC exchanges and dispatching exchanges, and verify feeding, dial tone and on-hook state channel by channel.
FXS side against user terminals: connect to telephones and fax machines, verify ringing, caller ID (CID) and call quality channel by channel, and attach labels according to user names.
Cable routing: lay voice channel cables and E1 coaxial cables separately, away from strong current and variable-frequency equipment; after crimping connectors, verify against labels to reduce accidental unplugging.
How to use the 2.5G dual optical ports and 1+1 protection for optical ports
IDM 120N-GP provides 2 2.5G SFP optical interfaces, i.e. 2.5G dual optical ports, and can provide 1+1 protection for optical ports: the two optical paths work as active and standby. When the active optical path has a fiber break or abnormal received optical power, services are automatically switched over to the standby optical path inside the equipment, without manual intervention at the far end or at service terminals, achieving seamless switchover on private network link failure.
The two optical ports can be connected to routes in two different directions respectively, or one can carry services while the other is reserved as a backup channel. The SFP slots allow replacement of optical modules according to line distance; single-mode is the standard configuration, multimode is optional for short distances, and 1310nm and 1550nm wavelengths are selected in pairs according to the far-end module. Spare parts only need modules of the same model. This protection mechanism is a key element of link reliability in government private network optical fiber communication solutions, military emergency communications vehicle solutions and rail transit communication solutions.

Figure 2: Rear panel interface layout of the IDM 120N-GP telephone optical multiplexer, showing 2 2.5G SFP optical ports, 4 groups of E1 coaxial interfaces, 2 gigabit Ethernet ports and 120 telephone terminals
What on-site problems can 120 voice channels and dual-optical-port protection in a single unit solve
Capacity expansion at private network nodes often involves three issues at the same time: voice channels are concentrated but rack space is limited; once a link is interrupted, the entire section of services is affected; and telephones and data each occupy a pair of fiber cores. IDM 120N-GP packs 120 voice channels, 4 groups of E1 and 2 gigabit data channels into one 19-inch 3U device, and its three differentiated capabilities address these three issues respectively.
Differentiated capability | Value to private network nodes |
|---|---|
120 FXO/FXS channels in a single unit, with a 19-inch 3U architecture for high-density voice access | One 3U device achieves the subscriber line capacity that previously required multiple stacked voice devices, reducing rack space, power supply modules and wiring quantities at the same time |
2 2.5G SFP optical ports support 1+1 protection for optical ports, with automatic switchover on fiber break without manual intervention | When the active optical path has a fiber break or abnormal received optical power, services are automatically switched over to the standby optical path, so duty personnel do not need to visit the site to move fibers, and link continuity is better guaranteed |
4 groups of E1 transparent transmission + 2 independent wire-speed gigabit Ethernet ports, carrying three types of services over one pair of optical fibers | Dispatch telephones, E1 leased lines and two gigabit data channels are transmitted simultaneously over one pair of optical fibers, with monitoring and office services each occupying one channel and not competing for bandwidth |
What functions and interfaces does the IDM 120N-GP telephone optical multiplexer have
The functions of IDM 120N-GP cover three categories: high-density voice access, optical port redundancy protection and multi-service same-fiber transmission. The role and applicable conditions of each capability are listed in the table below. During selection and acceptance, verify the interface quantity, interface type and protection mode row by row against the site service list, so as to avoid discovering interface mismatches only after the equipment arrives.
Function | Description |
|---|---|
19-inch 3U chassis architecture | Adopts a standard 19-inch 3U chassis structure, facilitating installation in existing private network cabinets with minimal equipment room renovation |
2.5G SFP dual optical ports and 1+1 protection for optical ports | Provides 2 2.5G SFP optical interfaces and can provide 1+1 protection for optical ports, with services automatically switched over to the standby optical path when the active optical path fails |
120 FXO/FXS interfaces | Provides 120 FXO/FXS interfaces as defined by the standard; FXO connects to the exchange side and FXS connects to the telephone side, achieving high-density voice access in a single unit |
2 independent wire-speed 1000M Ethernet ports | Provides 2 independent wire-speed 1000M Ethernet interfaces; the two gigabit ports forward independently, so services do not compete for bandwidth |
4 groups of E1 interfaces with transparent transmission | Provides 4 groups of E1 interfaces and supports transparent transmission mode, with a bit rate of 2048Kbps and HDB3 line coding; services are transmitted as they are without changing the time slot content |
Function control switch and alarm indication | Provides comprehensive function control switch and alarm indication functions, facilitating on-site commissioning and fault location |
Key specifications: optical interfaces, E1, Ethernet and power supply
The specifications are listed in five parts: optical interfaces, E1 channels, Ethernet interfaces, voice channel interfaces and power supply environment, with values taken from IDM 120N-GP product documentation. The link budget is calculated from transmit optical power and receiver sensitivity, and the site power supply capacity is calculated from overall power consumption; both are taken according to the specifications in the table to avoid a second order change.
Item | Parameter/Specification | Description/Applicable Conditions |
|---|---|---|
Optical interface type | SFP | Pluggable optical module, easy to replace by distance and to keep as spare parts |
Fiber mode | Single-mode (multi-mode optional) | Selected according to line distance and fiber core conditions |
Optical fiber rate | 2.5Gbps | Telephone, Ethernet and E1 services share the bandwidth of this optical path |
Wavelength | 1310nm/1550nm | Two wavelengths selectable, paired with the module at the opposite end |
Transmit optical power | -1~-3dBm | Typical single-mode value; subject to actual measurement with an optical power meter |
Receiver sensitivity | Better than -24dBm | The link loss budget can be calculated on this basis |
Optical port configuration | 2 SFP, 1+1 protection supported | Automatic switchover between active and standby optical paths |
E1 bit rate | 2048Kbps | HDB3 line coding |
E1 standard protocol | ITU-T G.703 | Standard E1 interface specification |
E1 impedance | 75 Ω | Matched with the E1 interface of the interfacing device |
E1 frame structure/mode | PCM30/31 / transparent transmission | Services are transmitted as they are, without changing the time slot content |
Ethernet interface | RJ45 | 2 independent wire-speed 1000M |
Ethernet transmission rate | 10M/100M/1000M | Compliant with IEEE802.3, full/half duplex adaptive |
Voice channel interface capacity | 120-channel FXO/FXS | 120 interfaces as defined by the standard |
FXO/FXS audio range | 300Hz~3400Hz | Telephone voice channel bandwidth |
FXO/FXS compression | ITU G.711 A-law | 64Kbps PCM encoding |
FXO/FXS loop current | 25mA per channel | Feeding capability of each voice channel |
Chassis structure | 19-inch 3U | Easy to install in a standard cabinet |
Power supply mode | DC-48V / AC220V / dual power supply | Dual power supply access improves power supply reliability |
Overall power consumption | ≤100W | Overall value including service cards and optical modules |
Operating temperature | 0℃~40℃ | Equipment room environment |
Humidity | ≤90% (non-condensing) | Upper limit of relative humidity |
As a professional optical multiplexer manufacturer, Raytrans provides this telephone optical multiplexer, which can flexibly adapt to diverse scenario requirements such as government private network optical fiber communication solutions, military emergency communications vehicle solutions, and rail transit communication solutions.
Typical Application Scenarios
The IDM 120N-GP is deployed as a pair in point-to-point mode: one unit at the service site and one at the central equipment room or centralized control station. The two ends are directly connected over optical fiber, and the telephone, E1 and Ethernet services are restored at the central side and then connected back to the existing switching and transmission devices. As a typical product showcase, this device is suitable for private network aggregation nodes with concentrated voice channels and a simultaneous need for gigabit data backhaul, and plays the role of multi-service integrated access among telephone optical multiplexer products.

Figure 3: Point-to-point networking schematic of the IDM 120N-GP telephone optical multiplexer, with the two ends interconnected through 2.5G SFP optical ports with 1+1 protection and telephone, E1 and gigabit services restored
Electric Power Private Network: Dispatch Telephone, E1 Leased Line and In-Station Data Backhaul over the Same Fiber
Between a substation and a dispatch station, dispatch telephone, automated E1 leased lines and in-station Ethernet data need to be transmitted simultaneously. One IDM 120N-GP is installed at each site, and a pair of 2.5Gbps single-mode optical fibers multiplexes and transmits the 120 voice channels, 4 groups of E1 channels and two gigabit data channels between stations, replacing stacked devices and multiple line rentals and demonstrating the intensive advantage of the multi-service optical multiplexer in electric power private networks.
1+1 protection for optical ports enables automatic service switchover when the active optical path fails, so there is no need to wait for personnel to attend on site and switch fibers during unattended periods. The overall power consumption does not exceed 100W, and DC-48V and AC220V dual power supply access is supported, so power can be taken directly from either the in-station communication power supply or the station service power.
Rail Transit Communication: Centralized Access of Official Telephone, E1 Channels and Monitoring Data at Stations and Depots
Rail transit stations, depots and trackside sites are distributed, and the E1 channels and monitoring data of official telephone, signaling and fare collection systems are often carried on different cables. The IDM 120N-GP multiplexes 120 voice channels of official telephone at the station side, 4 groups of E1 transparent transmission channels and 2 channels of gigabit data onto a pair of optical fibers for backhaul to the control center, making it a suitable model for distributed-site scenarios in rail transit communication solutions.
The two Gigabit ports each perform independent wire-speed forwarding, so monitoring data and office services are carried in isolation without contending for bandwidth, and only a pair of fiber cores is occupied between stations. Sections with tight existing optical cable resources do not need new laying, and capacity expansion only requires adding a pair of devices and a pair of patch cords per station.
Military/Government Private Networks: High-Capacity Voice Channel and Data Integrated Access at Remote Stations
In government private network and military emergency communications scenarios, remote stations, duty posts and storage areas have limited on-site maintenance personnel, and equipment room conditions are relatively standard. The IDM 120N-GP supports DC-48V and AC220V dual power supply access and can be installed in a 19-inch standard cabinet with temperature control; overall power consumption does not exceed 100W, so existing power supply capacity can usually handle it directly, meeting the requirements of government private network optical fiber communication solutions and military emergency communications vehicle solutions for device compactness and power supply adaptability.
The 1+1 protection for optical ports on the 2.5G dual optical ports enables seamless switchover in the event of a private network link failure, and the function control switch and alarm indication on the front panel facilitate on-site commissioning and fault locating. Duty personnel can narrow the failure down to the device, the optical cable or the opposite end simply by the indicator LED status, reducing the number of site visits for inspection.

Figure 4: Close-up of the operating status and alarm indication panel of the IDM 120N-GP telephone optical multiplexer, showing the function control switch and optical path alarm indicator LEDs
Selection and Deployment Recommendations
The IDM 120N-GP 2.5G dual optical port 120-channel telephone optical multiplexer is suitable for private network aggregation nodes with concentrated voice channels that also require gigabit data backhaul and E1 leased line transparent transmission. During selection, first determine the 120-channel FXO/FXS interface allocation according to voice channel direction and quantity, then select the optical module between single-mode and multi-mode and between 1310nm and 1550nm according to line conditions; if networking as a gigabit network optical multiplexer, the two Gigabit ports can forward independently at wire speed.
Calculate the link budget using a transmit optical power of -1 to -3dBm and a receiver sensitivity better than -24dBm, and select the power supply among DC-48V, AC220V or dual power supply according to on-site conditions. Enable 1+1 protection for optical ports at sites with high continuity requirements; for the specific configuration, it is recommended to confirm with optical multiplexer manufacturers such as Raytrans based on project requirements.