Communication Room/Base Station Knowledge

📅Oct 10, 2012
Brief:Communication Room/Base Station Product Applicability Conditions: Access network rooms/base stations with high power consumption; fresh air energy-saving systems are suitable for rooms/base stations with good ventilation and ideal surrounding environment; not suitable for installation near dusty roads, or factories with high dust levels such as cement plants or building material processing plants, to ensure the filter replacement cycle exceeds 30 days; not suitable for rooms/base stations with high humidity; not recommended for rooms with strict cleanliness requirements.
Communication Room/Base Station Knowledge

[Communication Room](http://www,

    Product Applicability Conditions

Access network rooms/base stations with high power consumption; fresh air energy-saving systems are suitable for rooms/base stations with good ventilation and ideal surrounding environment; not suitable for installation near dusty roads, or factories with high dust levels such as cement plants or building material processing plants, to ensure the filter replacement cycle exceeds 30 days; not suitable for rooms/base stations with high humidity; not recommended for rooms with strict cleanliness requirements.

    Product Functions

When installed in base stations/rooms, this product works in coordination with air conditioners. When the fresh air unit operating conditions are met, the air conditioner is turned off, and the fresh air unit regulates the temperature of the base station/room instead, saving electricity and extending the service life of the air conditioner compressor, thereby reducing enterprise operating costs. The annual power saving rate ranges from 20% to 60%.

    Product Advantages and Features

During equipment installation, the traditional practice of cutting square holes in the room wall is abandoned, eliminating safety hazards caused by hole cutting and effectively addressing issues such as base station theft prevention and small animal intrusion; high-performance temperature and humidity sensors are adopted, and the coordination between the fresh air unit and the air conditioner is fully controlled by temperature, so the power saving rate of the fresh air unit is entirely determined by the accuracy of the temperature and humidity sensors; the filter of the fresh air unit is specially treated, making disassembly and cleaning very convenient, and it can be reused after cleaning, reducing operation and maintenance costs; the intake air valve and exhaust air valve are specially treated at the connection with the wall, fully isolating indoor and outdoor air to meet gas fire extinguishing requirements.